CRS504-4XQ-INYour most affordable, compact, energy-efficient doorway to the world of 100 Gigabit networking. This switch is the next step in upgrading existing 10 or 25 Gigabit networks. Multiple powering options, dual hot-swap power supplies.
Our 100 Gigabit family keeps expanding – you’ve already seen the incredible CCR2216 100 Gigabit router. Now it’s time for a matching switch – theCRS504-4XQ-IN. The small size combined with the low power consumption(25W without attachments!)is perfect to start expanding 100 Gigabit networking in everyday setups. This speed is no longer limited to data centers, ISPs, and large offices. You too can upgrade your 10 or 25 Gigabit network and join the one hundred club!
There are four 100 Gigabit QSFP28 ports.Use them to connect other 100 Gigabit devices or grab a breakout cable to connect multiple 25 Gigabit devices: each port is connected to four 25 Gigabit lines, allowing you to connect 16 x 25 Gigabit devices. In fact, you can mix and match all kinds of connections this way: 100 Gigabits on one port, 40 Gigabits on the other, 4x25 Gigabits on the third, and maybe even some 10G or 1G cables on the fourth. The mightyMarvell DX4310 switch-chipwill handle everything without breaking a sweat!
Obviously, there is an Ethernet port for management purposes as well.
We’ve been using this switch for quite some time now in the Genomics Data Network project. A high-capacity data network for our local scientists working on ground-breaking cancer treatments. Genome data can take up a lot of space, so you need exceptionally fast connections there. Also, with these devices, Latvia became the first Baltic country to establish a 100 Gigabit connection to the pan-European research network.
With multiple powering options and the ability to be mounted on the wall, this switch will make any system administrator happy.
All tests are done with Xena Networks specialized test equipment (XenaBay),and done according to RFC2544 (Xena2544)
Max throughput is determined with 30+ second attempts with 0,1% packet loss tolerance in 64, 512, 1518 byte packet sizes
Test results show device maximum performance, and are reached using mentioned hardware and software configuration, different configurations most likely will result in lower results
The device has an operating system preinstalled and licensed. No separate purchase is necessary and the product is ready to use. The device includes free software updates for the life of the product or a minimum of 5 years starting from date of purchase..
С настоящето, "Mikrotikls SIA", декларира, че CRS504-4XQ-IN е в съответствие със съществените изисквания и другитеприложими разпоредби на Директива 2014/30/EC.
[CZ] Czech
"Mikrotikls SIA" tímto prohlašuje, že CRS504-4XQ-IN splňuje základní požadavky a všechna příslušná ustanoveni Směrnice 2014/30/ES.
[DK] Danish
Undertegnede "Mikrotikls SIA" erklærer herved, at følgende udstyr CRS504-4XQ-IN overholder de væsentlige krav og øvrige relevante krav i direktiv 2014/30/EF.
[DE] German
Hiermit erklärt "Mikrotikls SIA", dass sich das Gerät CRS504-4XQ-IN in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 2014/30/EG befindet.
[EE] Estonian
Käesolevaga kinnitab "Mikrotikls SIA" seadme CRS504-4XQ-IN vastavust direktiivi 2014/30/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.
[GR] Greek
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Ο ΚΑΤΑΣΚΕΥΑΣΤΗΣ "Mikrotikls SIA" ΔΗΛΩΝΕΙ ΟΤΙ CRS504-4XQ-IN ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 2014/30/ΕΚ
[EN] English
Hereby, "Mikrotikls SIA", declares that this CRS504-4XQ-IN is in compliance with the essential requirements and other relevant provisions of Directive 2014/30/EC.
[ES] Spanish
关于现在,“新航Mikrotikls雷竞技网站”,declara este CRS504-4XQ-IN cumple con los requisitos esenciales y otras exigencias relevantes de la Directiva 2014/30/EC.
[IT] Italian
Con la presente "Mikrotikls SIA" dichiara che questo CRS504-4XQ-IN è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 2014/30/CE.
[LV] Latvian
Ar šo "Mikrotikls SIA" deklarē, ka CRS504-4XQ-IN atbilst Direktīvas 2014/30/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.
[LT] Lithuanian
Šiuo "Mikrotikls SIA" deklaruoja, kad šis CRS504-4XQ-IN atitinka esminius reikalavimus ir kitas 2014/30/EB Direktyvos nuostatas
[HU] Hungarian
A "Mikrotikls SIA" ezzennel kijelenti, hogy a CRS504-4XQ-IN típusú beren-dezés teljesíti az alapvető követelményeket és más 2014/30/EK irányelvben meghatározott vonatkozó rendelkezéseket.
[NL] Dutch
Hierbij verklaart "Mikrotikls SIA" dat het toestel l CRS504-4XQ-IN in overeenstemming is met de essentiële eisen en de andere relevante bepalin-gen van richtlijn 2014/30/EG.
[PL] Polish
Niniejszym "Mikrotikls SIA" deklaruje że CRS504-4XQ-IN jest zgodny z zasadniczymi wymaganiami i innymi właściwymi postanowieniami Dyrektywy 2014/30/EC.
[PT] Portuguese
Eu, "Mikrotikls SIA", declaro que o CRS504-4XQ-IN cumpre os requisitos essenciais e outras provisões relevantes da Directiva 2014/30/EC.
(RO)罗马尼亚
Prin prezenta, "Mikrotikls SIA", declară că aparatul CRS504-4XQ-IN este în conformitate cu cerinţele esenţiale şi cu alte prevederi pertinente ale Directivei 2014/30/CE.
[SK] Slovak
"Mikrotikls SIA" týmto vyhlasuje, že CRS504-4XQ-IN spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 2014/30/ES.
[SI] Slovenian
"Mikrotikls SIA" izjavlja, da je ta CRS504-4XQ-IN v skladu z bistvenimi zahtevami in drugimi relevantnimi določili direktive 2014/30/ES.
[FI] Finish
"Mikrotikls SIA" vakuuttaa täten että CRS504-4XQ-IN tyyppinen laite on direktiivin 2014/30/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
[SE] Swedish
Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i direktiv 2014/30/EC.
[NO] Norwegian
"Mikrotikls SIA", Erklærer herved at CRS504-4XQ-IN er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 2014/30/EF.